Skip to main content Skip to complementary content

tInfiniteLoop Standard properties

These properties are used to configure tInfiniteLoop running in the Standard Job framework.

The Standard tInfiniteLoop component belongs to the Orchestration family.

The component in this framework is available in all Talend products.

Basic settings

Wait at each iteration (in milliseconds)

Enter the time delay between iterations.

Advanced settings

tStatCatcher Statistics

Select this check box to collect the log data at a component level.

Global Variables

Global Variables

ERROR_MESSAGE: the error message generated by the component when an error occurs. This is an After variable and it returns a string. This variable functions only if the Die on error check box is cleared, if the component has this check box.

CURRENT_ITERATION: the sequence number of the current iteration. This is a Flow variable and it returns an integer.

A Flow variable functions during the execution of a component while an After variable functions after the execution of the component.

To fill up a field or expression with a variable, press Ctrl + Space to access the variable list and choose the variable to use from it.

For further information about variables, see Talend Studio User Guide.

Usage

Usage rule

tInifniteLoop is an input component and requires an Iterate link to connect it to the following component.

Connections

Outgoing links (from this component to another):

Row: Iterate

Trigger: On Subjob Ok; On Subjob Error; Run if; On Component Ok; On Component Error.

Incoming links (from one component to this one):

Row: Iterate;

Trigger: On Subjob Ok; On Subjob Error; Run if; On Component Ok; On Component Error; Synchronize; Parallelize.

For further information regarding connections, see Talend Studio User Guide.